• ZrO2000 Fast Response Oxygen Analyzer with a measuring range of 0.1 PPM to 100%. Input voltage 90-264 VAC, 50-60Hz. Two scalable analog outputs are provided, 4-20 mADC and 0-20 mADC. Included is a easy to read, six digit backlit LCD as well as two (2) SPDT Form C contacts rated 10A @ 30VDC/115/240 VAC. Note: It is essential that the metal sample tubing used to connect to the ZRO2000 be of oxygen service quality (no residual oils or particles on the inner surfaces). In addition, the sample gas should not contain any reducing gases such as any hydrocarbon based gases, carbon monoxide, or hydrogen. Gases such as these can introduce significant error into the oxygen readings. If those gases are present, Alpha Omega Instruments does have alternative sensor technology to offer.
    Not in the US or Canada - Request a Quote
    Other Configurations Available: Get a Quote
    • Advanced Solid State Sensor
    • Measures parts PPM to 100% oxygen
    • Non-depleting oxygen sensor
    • 24 bit processing digital technology
    • Responds in milliseconds
    For a full list of product Specifications and Resources click here. Standard Lead time: Due to increased demand, current lead time is 8-10 weeks.
  • Pair of 24VDC Valves that together with a PLC or other device can be programmed to isolate the oxygen sensor (days ARO) 3-5.
    Not in the US or Canada - Request a Quote
  • Pair of 220VAC Valves that together with a PLC or other device can be programmed to isolate the oxygen sensor (days ARO) 3-5.
    Not in the US or Canada - Request a Quote
  • Two (2) AC powered (115 VAC) solenoid valves installed on the sample gas inlet and outlet used to isolate the oxygen sensor. The valves have been wired to an internally mounted terminal strip to provide the user with the ability to wire an external ON/OFF switch (supplied by user). If the analyzer has been equipped with an optional sample pump, the terminal strip will be configured so that an external ON/OFF pump switch (customer supplied) can be used.  For order with Series 3000 and 3520 analyzers and Series 3500 and 3510 transmitters only. Standard Lead time to Ship, (days ARO): 3-6
    Not in the US or Canada - Request a Quote
  • Swagelok - Spare Filter Elements - SS-4TF-2 Standard Lead time to Ship, (days ARO): 3-5
    Not in the US or Canada - Request a Quote
  • Swagelok - High Capacity Sample Filter- 316 stainless steel (SS) body with 316 SS filter element. Recommended when particles are >5 microns. The filter is equipped with 1/4" compression fittings. (Replaces Old PN: 295S, 395S – if replacing in an existing setup check that SWAGELOK is indicated on the side fo the filter housing) Standard Lead time to Ship, (days ARO): 3-5
    Not in the US or Canada - Request a Quote
  • Stainless Steel Flow Control Needle (Old P/N: 2FLV, 3FLV, ZR-FLV)
    Not in the US or Canada - Request a Quote
  • Series 3500 Percent Oxygen Transmitter with a single range of 0-500, 0-1,000, or 0-10,000 ppm available online. Looped powered at 14-32 VDC. Series 3500 includes the following:
    1. Accurate and dependable trace oxygen measurements in a variety of background gases
    2. Long-life Ambient Temperature Electrochemical Sensor
    3. NEMA 4 Enclosure
    4. 4-10 mADC output
    5. Factory calibration, NIST calibration certificates available upon request
    For a full list of product Specifications and Resources click here. Standard Lead time: Due to increased demand, current lead time is 5 weeks. *Select a model from the drop down list to see included features. Other Configurations Available: Get a Quote
    Not in the US or Canada - Request a Quote
  • *Select a model from the drop down list to see price and included features. If you are unsure of the configuration for you application please contact the factory at 401-333-8580 or 800-262-5977 (US and Canada) or contact us. *pictured with optional equipment Standard Lead time: Due to increased demand, current lead time is 4 weeks. For a full list of product Specifications and Resources click here.
    Not in the US or Canada - Request a Quote
    Other Configurations Available: Get a Quote *Select a model from the drop down list to see price and included features.
  • Series 2000 Microprocessor Based Percent Oxygen Analyzer with up to 3 measuring ranges. Input power is universal AC (90-264VAC), 50-60Hz. The Series 2000 features a long-life electrochemical sensor. Other features include three oxygen alarms with relays, two analog outputs (4-20 mADC and 0-2 VDC), and instrument diagnostics. The analyzer enclosure and electronics are configured for bench-top or portable use and comes equipped with a carrying handle. For a full list of product Specifications and Resources click here. Standard Lead time: Due to increased demand, current lead time is 5 weeks. *Select a model from the drop down list to see price and included features. Other Configurations Available: Get a Quote
    Not in the US or Canada - Request a Quote
  • Series 1300 Oxygen Deficiency Monitor. Input power is 90-264 AC, 50-60Hz and is accessible with the six foot power cord supplied with the instrument. The monitor is equipped with one (1) local oxygen sensor.
    • The Series 1300 quoted above includes the following:
    • "Extended Life" Sensor with EES.
    • Stable Output - greatly reduced calibration.
    • Factory Calibration / Fast Out-Of-Box Start-up.
    • FULL 3-year electronics warranty.
    • FULL 3-year sensor warranty.
    • Four oxygen alarm relay contacts each rated at 10 amps.
    • Two scalable analog outputs (4-20 mADC and 0-20 mADC).
    • Built-in data logger.
    • A built-in audible alarm (85 dB nominal) is included in the Series 1300 electronics enclosure as is front panel visual alarm indications via the LCD.
    • RS-232 serial communications.
    For a full list of product Specifications and Resources click here. Standard Lead time: Due to increased demand, current lead time is 4 weeks *Select a model from the drop down list to see price and included features.
    Not in the US or Canada - Request a Quote
  • Replacement 1300 Remote Cable 10 feet. (days ARO) 3-5 Replacement Sample Pump with AC Plug (115 VAC/50-60 Hz) for Series 2000, 2510, 3000, 3510.
    Not in the US or Canada - Request a Quote
Go to Top